Description / Abstract:
This test method is for the determination of the
totalconcentration of acetone, p-chlorobenzotrifluoride, methyl
acetate, or t-butyl acetate, or combination of any of the four, in
solvent-reducible and water-reducible paints, coatings, resins, and
raw materials. Because unknown compounds that co-elute with the
analyte being measured or with the internal standard, will lead to
erroneous results, this test method should only be used for
materials of known composition so that the possibility of
interferences can be eliminated. The established working range of
this test method is from 1 % to 100 % for each analyte by
weight.
The values stated in SI units are to be regarded as standard. No
other units of measurement are included in this standard.
This standard does not purport to address all of the safety
concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and
health practices and determine the applicability of regulatory
limitations prior to use.