More info
Description / Abstract:
This Standard covers plumbing supply fittings and accessories
located between the supply stop and the terminal fitting,
inclusive, as follows:
(a) automatic compensating valves for individual wall-mounted
showering systems;
(b) bath and shower supply fittings;
(c) bidet supply fittings;
(d) clothes washer supply fittings;
(e) drinking fountain supply fittings;
(f) humidifier supply stops;
(g) kitchen, sink, and lavatory supply fittings;
(h) laundry tub supply fittings;
(i) lawn and sediment faucets;
(j) metering and self-closing supply fittings;
(k) shower heads, hand-held showers, and body sprays; and
(l) supply stops.
This Standard does not cover
(a) plumbing waste fittings, which are covered by ASME
A112.18.2/CSA B125.2;
(b) other devices (e.g., temperature-actuated in-line mixing
valves), which are covered by CSA B125.3 or other plumbing product
Standards; and
(c) flexible water connectors under continuous pressure, which
are covered by ASME A112.18.6/ CSA B125.6.
Except for push-fit fittings, this Standard does not cover pipes
and tubes or pipe and tube fittings.
In this Standard, "shall" is used to express a requirement,
i.e., a provision that the user is obliged to satisfy in order to
comply with the standard; "should" is used to express a
recommendation or that which is advised but not required; "may" is
used to express an option or that which is permissible within the
limits of the standard; and "can" is used to express possibility or
capability.
Notes accompanying clauses do not include requirements or
alternative requirements; the purpose of a note accompanying a
clause is to separate from the text explanatory or informative
material.
Notes to tables and figures are considered part of the table or
figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative
(non-mandatory) to define their application.
SI units are the units of record in Canada. In this Standard,
the inch/pound units are shown in parentheses
The values stated in each measurement system are
equivalent in application; however, each system is to be used
independently. Combining values from the two measurement systems
can result in non-conformance with this Standard.
All references to gallons are to U.S. gallons.
For information on the conversion criteria used in this